PC-1TL, PM-2, PCU-200 Spiral
Viscometers
When speaking of solder paste, one parameter that is often discussed is
viscosity. Viscosity is important as a paste that is too thick (high viscosity) may lead
to a bad print in the form of an insufficient filet. A paste that is too thin (low
viscosity) may lead to filet slumping. In order to test that a paste has the proper
thickness for optimal printing, the paste's viscosity should be checked with an accurate
and repeatable viscometer.
It is important to bear in mind that there are basically two components to solder paste
viscosity measurement. They are the static viscosity and dynamic viscosity. Static
viscosity is the viscosity of the solder paste as it is dispensed off of a tube or syringe
onto a screen printer. The dynamic viscosity, on the other, hand gives the variation in the
thixotropic behavior of the solder paste during the course of the screen printing process.
It is important to know the dynamic viscosity of a paste in order to predict its printing
characteristics.
Dynamic viscosity is gained by adding shear to solder paste. Shear is what the solder
paste encounters on a screen printer. Understanding how shear affects solder paste
viscosity is critical as it may help to limit printing problems.
The Malcom PC-1TL, PM-2, and PCU-200: Spiral Viscometers by design are able to
measure not only the static viscosity of solder paste at low rpm, but it can more
importantly measure the dynamic viscosity. This is due to the fact that Malcom applies a
true shear force onto the solder paste, simulating the forces that act on the paste on a
screen printer. By varying the rpm, one can find the shear sensitivity and thixotropic
index of the solder paste, something that could not be accurately done with most other
viscometers. Thus with a Malcom viscometer, the user can not only measure batch to batch
variation, but can also predict how the solder paste will perform on the screen printer.
Principle of Spiral Viscometers
The Malcom Viscometers
utilize a patented double cylinder spiral pump method. Malcom
Viscometers takes the double cylinder method step better. The inner cylinder has spiral
flutes making it resemble a screw. It is attached to a torque sensor. The outer cylinder
has an inlet scoop and exhaust openings. This rotates at a constant speed. Due to the
geometry of the two cylinders, the assembly is a type of pump. When in operation, the
paste is scooped into the gap between the cylinders, and slowly the pump speed becomes
constant. The length of the flutes are consistent, thus it follows
that both the shear rate and
shear time are also constant. Knowing these two values and the torque enable one to
find the
viscosity of the thixotropy, the adhesive force, and the viscoelasticity; properties
necessary for proper and successful screen printing. |
PM-2 Hand Held Spiral Viscometer
Features and
Benefits
- Patented spiral-pump sensor provides quick, easy, repeatable measurements.
- Compact, hand-held design allows convenient in-the-field measurements.
- Continuous measurement of Newtonian and non-Newtonian fluids with constant shear rate
and shear time.
- Easy to read, high-contrast LCD digital display of viscous values.
- Models available for three ranges of viscosity measurement.
- Re-calibration can be performed by user.
- Optional probe allows temperature measurement of sample.
- Satisfies international standards.
- Application includes pastes, paints, food, inks, cosmetics, etc.
|
Specifications
| Model number |
PM-2A |
PM-2B |
PM-2C |
| Measurement range |
50 - 5000 p |
2 - 200 p |
0.2 - 20 p |
*Specifications are subject to change without notice.
PC-1TL: Table-Top Spiral Viscometer
Features and
Benefits
- Unique spiral-pump design for faster, easier, more accurate viscosity measurement.
- Fixed shear rate and shear time - no complicated calculations required.
- Eliminates multiple measurements and averaging.
- +/- 2% repeatability - not user dependant.
- More consistent than conventional methods.
- Optional spiral cylinders allows a single unit to measure a wide range if viscosities,
including solder paste, adhesives, solder masks, thick-film, etc.
|
Specifications
| Model number |
Type A |
Type B |
Type C |
| Viscosity range |
50 - 10,000 p |
2 - 200 p |
20 - 2,000 cps |
*Specifications are subject to change without notice.
PCU-200 Laboratory Digital Spiral
Viscometer
Features and
Benefits
- Patented spiral-pump sensor provides quick, easy, repeatable measurements.
- Elimination of misprints due to incorrect paste conditions.
- Continuous measurement of Newtonian and non-Newtonian fluids with constant shear rate
and shear time.
- Automatic control of measurement according to JIS standards (PCU-203,
205) regardless of
operator skill.
- Acquisition of viscosity data for rheological analysis.
- Built in dot matrix printer allows logging of acquired measurements.
- Fully automatic temperature control of sample.
- Satisfies international standards.
- Application includes solder pastes, thick film pastes, solder resists,
liquid resists,
inks, etc.
|
Specifications
| Model number |
PCU-201 |
PCU-203 |
PCU-205 |
| Measurement range |
50 - 10,000 p |
50 - 10,000 p |
50 - 10,000 p |
| Automatic measurement |
|
JIS Standard method |
JIS plus On-line method |